ETHYLENE GLYCOL BASED

WITH SILICATE ADDITIVES

CONCENTRATE. UNIVERSAL

INTENDED FOR ALL TYPES OF ROOMS
COOLANT -65C
Теплоноситель
Article: 49122
Canister, 20kg

ADVANTAGES
20 kg
10 kg
LUMINESCENT DYE WILL SHOW WHERE THE LEAK IS
SERVICE LIFE - 10 YEARS
SYSTEM-SAFE, DOESN'T EXPAND EVEN WHEN FREEZING
CORROSION PROTECTION
HIGH HEAT CAPACITY
HIGH HEAT TRANSFER COEFFICIENT
Technical characteristics of heat carriers comply with GOST 33341-2015, SVNTS -65°C
HEAT CARRIER CONCENTRATE "SANFIX"
A high-quality new generation carrier is intended for use in heating systems with different types of heating boilers, in air conditioning systems and secondary circuits of refrigeration units operating in the temperature range from -65°C to +108°C.
Does not form carcinogenic compounds during operation. Not aggressive to plastic and rubber elements.
Used in accordance with the equipment manufacturer's instructions.

- Recommended for heating systems without a water circuit
- Recommended for air conditioning systems

Not recommended for use in: Electrode boilers of the Galan type / Systems with natural circulation / In systems with zinc coating of pipes.

COMPOSITION: premium ethylene glycol, prepared water, a complex of anti-foam and anti-corrosion additives, dye.

PRECAUTIONS: Do not take internally, in case of contact with eyes and skin - rinse with plenty of running water, in case of contact internally - consult a doctor. Avoid exposure to direct sunlight, keep out of reach of children and pets. Store and use at moderate and low temperatures down to -65°C.
Fire and explosion safe according to GOST 12.1.044. Non-hazardous cargo according to GOST 19433-88.
DISPOSAL: Waste generated during use of the product should be taken to specialized collection points, such as car service stations. It is prohibited to drain them into open ground, water supply systems or sewers.
PURPOSE
PREPARING THE SYSTEM BEFORE USE. Before filling the coolant, it is necessary to pre-flush the system and check for leaks. If a leak is detected, drain the liquid, eliminate the leaks and test again.
FILLING THE SYSTEM. Calculate the volume of the system required for filling by adding up the internal volumes of the heating elements, the boiler and all pipes. Check that the volume of the expansion tank is at least 10% of the total filling volume of the system. Fill the coolant into the system through the boiler cover or another opening in accordance with the instructions for your equipment. To improve circulation and reduce the viscosity of the coolant, adjust the pump power, setting the speed close to maximum.
Perform other settings in accordance with the instructions for your equipment.
When working with the coolant, be sure to use rubber gloves.
Not recommended: Dilute with ordinary water, this may lead to the precipitation of a sediment containing phenolic additives. Use in other economic activities. Mix this coolant with coolants from other manufacturers, as this may lead to the loss of the declared characteristics and properties.

Dilute with demineralized water:

Coolant (concentrate) / Water - Temperature, °C
4/1 -40°C
2/1 -30°C
1/1 - 20°C

ATTENTION! Read the instructions for use of your equipment for the possibility of replacing water with a coolant.
CONTACTS

Telephone
8 800 600 36 89
8 495 545 49 47
e-mail: info@sanfix.pro
address: 140002, Moscow region, city Lyubertsy, Lyubertsy, Oktyabrsky Prospekt, 1.